SAMPLING
The reliability of results in cork analyses depends on the representativeness of the sample. This requires the use of numerous samples, given the heterogeneity of the raw material.
Since there are no corks with zero contamination, the sampling plan must include acceptance and rejection criteria, expressed by LQA (Acceptable Quality Level) values.
Based on the experience developed in sensory analysis and TCA analysis, the sampling plan established by the inspection level, which can be ordinary or reduced, for an Acceptable Quality Level of 1.0, in accordance with UNI – ISO 2859/1, has been deemed suitable.
When the reduced inspection level is used and defectiveness values higher than Na (Acceptable number of defects) but lower than Nr (Number of defects that leads to rejection of the lot) are obtained, the analysis continues using another sample, with a size equal to that indicated by the ordinary inspection level.